Galaxy Series Ultra Lightweight RTCA/DO-160G Compliant Aircraft Grade 0.9-5 KVA UPS Systems

  • Formally Qualified to RTCA/DO-160, MIL-STD-1399, MIL-STD-461, MIL-S-901, MIL-STD-167, MIL-STD-810, MIL-STD-740, and DOD-STD-1399
  • Compact Chassis (1U – 5U Tall)
  • Ultra Lightweight Design
  • Power Factor Corrected Input (Single-Phase Input Models)
  • SNMP Communications
  • Lithium Iron Phosphate Batteries Available Optionally
  • Double-Conversion UPS Systems
  • Rack-Mount, Double-Conversion UPS Systems
  • Rugged UPS System
  • Military UPS System
  • True Online UPS Technology

More Details

WHEN EVERY POUND COUNTS! Nova’s Ultra Lightweight Galaxy-Series rugged, military UPS systems are high-reliability power sources specifically designed for demanding aircraft applications in high shock, vibration, humidity, and EMI environments in compliance to RTCA/DO-160, MIL-STD-461, and MIL-STD-810. These rugged UPS models utilize True On-Line technology, offering maximum field-proven reliability for severe environment and high reliability applications.

These are the UPSs of choice for all branches of the US Armed Forces, Boeing, EADS, and many other high profile airborne applications worldwide. Typically, these rugged UPS models have aircraft power input of 115/200 VAC, 400Hz, three-phase wye, although single-phase input is also available at no extra cost.

RTCA/DO-160G Qualified: Select units were tested successfully by Boeing and Rockwell Collins to meet RTCA/DO-160G for:

  • Rapid Decompression: Section 4 Cabin Pressure (8K) to Max Operating Alt (35K) in 15 sec; Hold for 10 min
  • Crash Safety Sustained: Section 7, Cat B – Up = 3.0g – Down = 6.0g – Fwd = 9.0g – Aft = 1.5g – Side =4.0g
  • Explosive Atmosphere: Non-Ignition Test Sec. 9.6.2, Cat E
  • Humidity: Section 6, paragraph 6.3.1 (Category A)
  • Random Vibration Testing: Section 8 (Category R, Fixed-Wing), paragraph 8.7.2, Figure 8-1: Aircraft Type 2, Test Category S, Zone 2, Curve B
  • Operational Shock Testing: Section 7 (Category B), paragraph 7.2, Standard operational, Peak value 6 g, Nominal duration 11 ms.

Additional Ruggedization to meet MIL-STD-810: The UPS System’s construction is extremely robust, and ruggedized throughout. All components and modules within the UPS are mounted using additional steel brackets and heavy-duty stainless-steel hardware, which is then further secured using Loctite and RTV where required. All boards are conformal-coated (Acrylic MIL-I-46058 Type R) for maximum resistance to potential condensation and fungus growth. For additional protection against humidity, optional low-draw heating elements can be included within the unit, and optional drain holes can be placed strategically in the base of the chassis to allow any formed condensation to escape.

Partners

We provide system solutions for ground, airborne, naval, medical, test, telecom and industrial requirements.
Diagnostic testing is performed on integrated products and test reports issued.